Digital Storage Oscilloscope
Feature: Dual channel adjustable 0-32V/30V/60V output Fixed 2.5V/3.3V/5V/3A selectable output (for DPS-3033T only). Brandnew design, Digital encoding regulated with 4 groups Memory and Recall Panel lock function to avoid wrong operation Preset current&voltage limitied point Protection voltage and current limit set with password to prevent damage voltage or current output DPS series automatically switch between constant voltage and constant current mode Overload protection Output standby function Constant Voltage, Constand Current Low ripple noise low temperature drift Series or parallel inner connection in the Tracking mode Intelligent fan control Over temperature alert Specification: Model DPS-3033T DPS-3055T DPS-6022T Output 0-32V/3A×2 0-30V/5A×2 0-60V/2A×2 Constant Voltage Operation Ling regulation ≤0.01%+3mV ≤0.02%+3mV ≤0.02%+5mV Load regulation ≤0.01%+3mV ≤0.02%+5mV ≤0.02%+5mV Recover Time ≤100μs Ripple& Noise ≤2mV rms(5Hz~1MHz) ≤3mV(5Hz~1MHz) Temperature coefficient ≤300PPm/℃ Constant Current Operation: Line regulation ≤0.2%+3mA ≤0.3%+3mA ≤0.3%+3mA Load regulation ≤0.2%+3mA ≤0.3%+5mA ≤0.3%+3mA Current Ripple ≤3mA rms Parallel: Line regulation ≤0.01%+3mV ≤0.05%+3mV ≤0.05%+5mV Load regulation ≤0.01%+3mV ≤0.05%+5mV ≤0.05%+5mV Series : Line regulation ≤0.01%+5mV Load regulation ≤300mV Slave tracking error≤CH1 output X0.5% +10mV (No load, add≤300mV Load regulation) CH3 output (For DPS-3033T only) Regulation Line regulation≤5mV,Load regulation≤15 mV Ripple& Noise ≤2mV rms Range of Voltage 2.5V、3.3V、5V(Selectable) Output Current 3A Insulation degree Between chassis and output terminal:≥20MΩ/500VDC Between chassis and AC cord:≥30 MΩ/500VDC Display accuracy 3&1/2 Digit display≤±0.5%+2d Weight 7KG Size 30cm(L)×22 cm(W)×15cm(H)
Feature: Dual channel adjustable 0-32V/30V/60V output Fixed 2.5V/3.3V/5V/3A selectable output (for DPS-3033T only). Brandnew design, Digital encoding regulated with 4 groups Memory and Recall Panel lock function to avoid wrong operation Preset current&voltage limitied point Protection voltage and current limit set with password to prevent damage voltage or current output DPS series automatically switch between constant voltage and constant current mode Overload protection Output standby function Constant Voltage, Constand Current Low ripple noise low temperature drift Series or parallel inner connection in the Tracking mode Intelligent fan control Over temperature alert
Specification:
Output
0-32V/3A×2
0-30V/5A×2
0-60V/2A×2
Ling regulation
≤0.01%+3mV
≤0.02%+3mV
≤0.02%+5mV
Load regulation
Ripple& Noise
≤2mV rms(5Hz~1MHz)
Line regulation
≤0.2%+3mA
≤0.3%+3mA
≤0.3%+5mA
Current Ripple
≤3mA rms
≤0.05%+3mV
≤0.05%+5mV
Regulation
Line regulation≤5mV,Load regulation≤15 mV
≤2mV rms
Range of Voltage
2.5V、3.3V、5V(Selectable)
Output Current
3A
Insulation degree
Between chassis and output terminal:≥20MΩ/500VDC
Between chassis and AC cord:≥30 MΩ/500VDC
Display accuracy
3&1/2 Digit display≤±0.5%+2d
Weight
7KG
Size