Digital Storage Oscilloscope

MDS-1102CA
  MPS-3003L-3/ 3003LK-3
  MPS-3005L-3/ 3005LK-3
MPS-3002S/ 3003S/ 3005S
  MPS-6003S
MPS-3010L-1
  MPS-1820L-1
  MPS-6005L-1
MPS-3010L-2
MPS-6005L-2
MPS-3020/7061
  MPS-7162/ 7163
MPS-7033/7052/7062/7101
DPS-3203TK-3
DPS-3033GL-3
Digital Regulated DC Power Supply
DPS-3033T
 
Genset Controller
EMS39
EMS907
EMS926
Toroidal transformer
For AV amplifier
For industrial contol
For light fittings
For medical euipments
For testingt equipment
MF0025G
 
 
MOS-620B/640B

20MHz/40MHz Oscilloscope with Built-in 1000:1 Attenuator Expanded Vertical Sensitivity to 10V~20V/DIV

Specification

 

  • VERTICAL AXIS
  • Sensitivity: 5mV~20V/DIV,12 steps in 1-2-5 sequence (X5 MAG: 1mV/DIV)
  • Sensitivity accuracy: ≤ 3% ( × 5 MAG: ≤ 5% )
  • Vernier vertical sensitivity: Continuously variable to 1/2.5 or less of panel-indicated value
  • Frequency
  • Bandwidth: DC~20MHz ( × 5MAG:DC~7MHz) / DC~40MHz (X5MAG: DC~15MHz)
  • AC coupling: Low limit frequency 10Hz.
  • (With reference to 100KHz, 8DIV. Frequency response with-3dB.)
  • Rise time:Approx.17.5nS( × 5MAG:Approx.50nS) / Approx. 9.5nS (X5MAG: Approx. 25nS)
  • Input impedance:Approx.1M Ω /Approx.25pF
  • Square wave characteristics: Overshoot: ≤ 5%(At 10mV/DIV range);
  • Other distortions and other ranges:5% added to the above value
  • DC balance shift: 5mV~5V/DIV; ±0.5DIV, 1mV~2mV/DIV±2.0DIV
  • Linearity: ≤± 0.1DIV of amplitude change when waveform of 2DIV at graticule center is moved vertically
  • Vertical modes: CH1: CH2 single channel;
  • DUAL: CH1 and CH2 are displayed simultaneously.
  • ALT or CHOP selectable at any sweep rate;
  • ADD: CH1+CH2 algebraic addition
  • Chopping repetition frequency: Approx.250KHz
  • Input coupling: AC, GND , DC
  • Maximum input voltage: 300Vpeak (AC: frequency 1KHz or lower);When set probe switch at 1:1, the maximum effective readout is 40Vp p(14Vrms at sine wave); or set probe switch at 10:1, the maximum effective readout is 400Vpp(140Vrms at sine wave).
  • Common mode rejection ratio: 50:1 or better at 50KHz sinusoidal wave. (When sensitivities of CH1 and CH2 are aet equally)
  • Isolation between channels(At 5mV/DIV range): > 1000:1 at 50KHz; > 30:1 at 20MHz/ > 30:1 at 40MHz
  • CH1 signal output: At least 20mV/DIV into a 50 Ω termination. Bandwidth is 50Hz to at least 5MHz
  • CH2 INV BAL: Balanced point variation: ≤ 2DIV(Reference at center graticule)
  • TRIGGERING
  • Triggering source: CH1, CH2, LINE, EXT
  • Coupling: AC:20Hz to full bandwidth
  • Slope: +/-
  • Sensitivity: 20Hz~2MHz:0.5DIV, TRIG-ALT:2DIV, EXT:200mV; 2~2MHz:1.5DIV; 20MHz~40MHz: 2DIV, TRIG-ALT:3DIV, EXT:800mV; TV: Sync pulse more than 1DIV (EXT:1V)
  • Triggering modes: AUTO; NORM ; TV-V ; TV-H; (Both TV-V and TV-H synchronize only when the synchronizing signal is negative)
  • EXT triggering signal input:
  • Input impedance: Approx:1M Ω /approx.25pF
  • Max. input voltage: 300V(DC+AC peak), AC: Frequency not higher than 1KHz
  • HORIZIONTAL AXIS
  • Sweep time: 0.2 μ Sec~0.5Sec/DIV, 20steps in 1-2-5 sequence;
  • Sweep time accuracy: ± 3%;
  • Vernier sweep time control: ≤ 1/2.5 of panel-indicated value;
  • Sweep magnification: 10 times;
  • × 10MAG sweep time accuracy: ±5 %(20nSec~50nSec are uncalibrated);
  • Linearity: ± 3%, × 10MAG: ±5 %(20nSec~50nSec are uncalibrated);
  • Position shift caused by × 10MAG: Within 2DIV. at CRT screen center
  • X-Y MODE:
  • Sensitivity: Same as vertical axis. (X-axis: CH1 input signal;Y-axis:CH2 input signal.);
  • Frequency bandwidth: DC to at least 500KHz;
  • X-Y phase difference: ≤ 3°at DC-50KHz
  • Z AXIS
  • Sensitivity: 5Vp-p (Positive-going signal decreases intensity);
  • Frequency bandwidth: DC~2MHz;
  • Input resistance: Approx.47K Ω ;
  • Maximum input voltage:3V(DC+AC peak, AC frequency ≤ 1KHz)
  • CALIBRATION VOLTAGE
  • Waveform: Positive-going square wave;
  • Frequency: Approx.1KHz; Duty ratio: Within 48:52;
  • Output voltage: 2Vp-p ± 2%;
  • CRT
  • Type: 6-inch rectangular type, internal graticule;
  • Phosphor:P31;
  • Acceleration voltage: Approx.2KV(20MHz) / Approxl12KV (40MHz);
  • Effective screen size: 8 × 10DIV (1DIV=10mm(0.39in);
  • Trace rotation: Provided

 

NOTE :
  • 20MHz/40MHz Dual Channel
  • High Sensitivity 1mV/DIV
  • Z Axis Input
  • CH1 Output
  • 10 times sweep magnification
  • TV Synchronization, X-Y mode
  • High luminance, internal graticule
  • Encoder for Sweep and Vert mode switch
  • ALT Triggering Function, simultaneous observation of two independant signalls
  • Triggering Level Lock Function
  • Buit in 1000:1 attenuator expanded vertical sensitivity to 10V~20V/DIV

 

©2006 Matrix Technology Inc All rights reserved
Add: Building.B, No.5 East Wing, Shangxue Technology City, Bantian, Longgang, Shenzhen, China 518129
Tel: 0086 755 61217025 Fax: 0086 755 61217015