WPS-L Series wide range programmable DC power supply
•Output voltage: 0~80V; Output current: 0~5/10/20/30A; Output power: 100/200/400/600W
•High-precision display with resolution: 1mV for voltage, 0.1mA for current
•DVM voltmeter measurement function
•Internal temperature monitoring function
•Standard RS-232/RS485/USB communication interfaces, compatible with SCPI and Modbus protocols
Product Brief Introduction
| Model | WPS100-8005L | WPS200-8010L | WPS400-8020L | WPS600-8030L | |
| Rated input voltage | AC220V/110V±10% | ||||
| Rated output voltage | 0~80V | 0~80V | 0~80V | 0~80V | |
| Rated output current | 0~5A | 0~10A | 0~20A | 0~30A | |
| Rated output power | 100W | 200W | 400W | 600W | |
| Load regulation rate | Voltage | ≤0.01%+3mV | ≤0.01%+10mV | ≤0.01%+30mV | ≤0.01%+30mV |
| Current | ≤0.05%+2mA | ≤0.05%+4mA | ≤0.05%+6mA | ≤0.1%+10mA | |
| Line regulation | Voltage | ≤001%+3mV | ≤0.01%+10mV | ≤0.01%+30mV | ≤0.01%+30mV |
| Current | ≤0.05%+2mA | ≤0.05%+4mA | ≤0.05%+6mA | ≤0.1%+10mA | |
| Setting value resolution | Voltage | 1mV | 1mV | 1mV | 1mV |
| Current | 0.1mA | 1mA | 1mA | 1mA | |
| Readback value resolution | Voltage | 1mV | 1mV | 1mV | 1mV |
| Current | 0.1mA | 1mA | 1mA | 1mA | |
| Setting accuracy (25℃±5℃) | Voltage | ≤0.03%+5mV | ≤0.03%+5mV | ≤0.03%+5mV | ≤0.03%+5mV |
| Current | ≤0.1%+3mA | ≤0.1%+5mA | ≤0.1%+10mA | ≤0.1%+15mA | |
| Readback accuracy (25℃±5℃) | Voltage | ≤0.03%+5mV | ≤0.03%+5mV | ≤0.03%+5mV | ≤0.03%+5mV |
| Current | ≤0.1%+3mA | ≤0.1%+5mA | ≤0.1%+10mA | ≤0.1%+15mA | |
| Ripple | Voltage | ≤5mVms | ≤5mVms | ≤8mVrs | ≤10mVrms |
| Current | ≤5mArms | ≤6mArms | ≤8mArms | ≤15mArms | |
| Rising time | ≤150mS(10%-90%) | ≤150mS(10%-90%) | ≤150mS(10%-90%) | ≤150mS(10%-90%) | |
| Falling time | ≤2S(10%-90%) | ≤2S(10%-90%) | ≤2S(10%-90%) | ≤2S(10%-90%) | |
| Size | mm | 255*110*380 | 255*110*475 | ||
| Weight | kg | 82 | 92 | 13.3 | 15.2 |
Product Brief Introduction
Product Description
The WPS-L series adopts wide-range power conversion architecture, realizing flexible voltage-current matching under fixed rated power to break the fixed V/A limitation of traditional single-range power supplies. The whole machine supports universal AC 110V/220V ±10% input, stable working environment of 0~40℃ and relative humidity below 80% non-condensing, storage temperature range from -15℃ to 70℃. Different models have fixed cabinet dimensions and net weights to meet desktop bench and cabinet rack installation demands.
In terms of output stability and measurement precision, all units deliver excellent load and line regulation performance. The minimum voltage load regulation reaches ≤0.01%+3mV, with ultra-low voltage ripple as low as 5mVrms to provide clean DC power for precision circuit testing. Under standard 25℃±5℃ test environment, voltage setting accuracy ≤0.03%+5mV, current setting accuracy varies by model according to rated current. The series maintains unified 1mV voltage setting and readback resolution; low-power 5A model uses 0.1mA current resolution, while other high-current models adopt 1mA current resolution. The voltage rise time is controlled within ≤150ms and fall time ≤2s, meeting fast power change test requirements.
For humanized front-panel operation, dual parameter input methods are provided: direct value entry via full numeric keypad, and fine adjustment via rotary knob. The instrument supports saving up to 5 groups of editable List test files, each with a maximum of 100 programmable steps and customizable dwell time to complete unattended cyclic aging tests. It supports storage and quick recall of common test parameters to improve repeated testing efficiency. Two exclusive built-in measurement and monitoring functions are standard: DVM independent voltmeter function that measures DC voltage from 0.001V to 80.000V without extra meters; internal temperature real-time monitoring to track equipment heat status during long-running tests. The rear panel reserves dedicated SENSE remote compensation terminals to eliminate voltage drop loss on long test wires, ensuring accurate voltage at the terminals of tested DUTs. Both front and rear output terminals are reserved to adapt different wiring layouts of test stations.
Comprehensive hardware safety protection system is embedded, consisting of OVP overvoltage protection, OCP overcurrent protection and OTP overtemperature protection. The power supply will automatically cut off output immediately once abnormal voltage, current or temperature is detected to protect both the instrument and electronic samples. Intelligent temperature-controlled fan adjusts rotation speed dynamically based on internal heat load, balancing low noise under light load and sufficient heat dissipation under full power output.
For automated test system integration, RS232, RS485 and USB communication interfaces are standard factory configurations, fully compatible with SCPI and Modbus remote control command sets to support upper computer parameter setting, real-time data reading and automatic test flow execution. LAN communication interface and external analog control function are optional accessories that can only be pre-installed before delivery and cannot be retrofitted by users. Standard delivery accessories include power cable, test leads, SENSE wire, RS232/RS485/USB connecting lines and official WPS-L user manual; dedicated product datasheet and programming files are downloadable from the official website for secondary development.
Application Scenarios
- Electronic Circuit R&D & PCB Prototype Debugging: Supply adjustable stable wide-range DC power for analog sensors, wireless modules and consumer electronic prototype performance verification.
- Electronic Component Batch Aging Testing: Utilize 100-step List sequence output and multi-cycle function to complete long-term aging screening of resistors, capacitors and power chips.
- Laboratory Precision Voltage Measurement: Leverage built-in DVM voltmeter to detect DC voltage of components without additional external measuring instruments.
- New Energy Small Battery Charge-Discharge Test: Simulate CV/CC charging curves for lithium batteries with adjustable voltage and current parameters.
- Automated ATE Test System Integration: Realize long-distance programmable remote control via RS232/RS485/USB SCPI/Modbus interfaces for mass production automatic test lines.
Product FAQ Dialogues
Q1 What resolution does WPS-L adopt for voltage and current setting?
Q2 What core built-in special measurement functions does the WPS-L series carry?
Q3 What is the List sequence output capability of WPS-L?
Q4 What communication interfaces and optional functions does WPS-L support?
Q5 What is the function of the SENSE terminal reserved on the rear panel of WPS-L?
| Standard Accessories: | Power Cable*1PC, RS-232, RS-485, SENSE, Test Lead*1PC, USB, User Manual |
|---|---|
| Optional Accessories (Manufacturer installed only): | LAN |