MPP‑P Series Wide Range Programmable DC Power Supply
Product Introduction
Product Description
Product selection
| Model | Voltage | Current | Power | Interface |
| MPP-1000P-60-30 | 60.000V | 30.000A | 1000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-1000P-100-15 | 100.00V | 15.000A | 1000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-1000P-200-8 | 200.00V | 8.0000A | 1000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-1000P-300-5 | 300.00V | 5.0000A | 1000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-2000P-45-100 | 45.000V | 100.00A | 2000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-2000P-60-80 | 60.000V | 80.000A | 2000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-2000P-80-60 | 80.000V | 60.000A | 2000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-2000P-100-45 | 100.00V | 45.000A | 2000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-2000P-150-30 | 150.00V | 30.000A | 2000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-2000P-200-23 | 200.00V | 23.000A | 2000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-2000P-300-15 | 300.00V | 15.000A | 2000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-2000P-400-12 | 400.00V | 12.000A | 2000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-2000P-500-9 | 500.00V | 9.0000A | 2000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-2000P-600-8 | 600.00V | 8.0000A | 2000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-3000P-45-100 | 45.000V | 100.00A | 3000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-3000P-60-80 | 60.000V | 80.000A | 3000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-3000P-80-60 | 80.000V | 60.000A | 3000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-3000P-100-45 | 100.00V | 45.000A | 3000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-3000P-150-30 | 150.00V | 30.000A | 3000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-3000P-200-23 | 200.00V | 23.000A | 3000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-3000P-300-15 | 300.00V | 15.000A | 3000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-3000P-400-12 | 400.00V | 12.000A | 3000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-3000P-500-9 | 500.00V | 9.0000A | 3000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-3000P-600-8 | 600.00V | 8.0000A | 3000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-100-100 | 100.00V | 100.00A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-150-67 | 150.00V | 67.000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-200-50 | 200.00V | 50.000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-250-40 | 250.00V | 40.000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-300-34 | 300.00V | 34.000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-400-25 | 400.00V | 25.000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-500-20 | 500.00V | 20.000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-600-17 | 600.00V | 17.000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-800-12 | 800.00V | 12.000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-1000-10 | 1000.0V | 10.000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-1200-8 | 1200.0V | 8.0000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-6000P-1500-4 | 1500.0V | 4.0000A | 6000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P-100-100 | 100.00V | 100.00A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P-150-67 | 150.00V | 67.000A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P-200-50 | 200.00V | 50.000A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P=250-40 | 250.00V | 40.000A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P-300-34 | 300.00V | 34.000A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P-400-25 | 400.00V | 25.000A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P-500-20 | 500.00V | 20.000A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P-600-17 | 600.00V | 17.000A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P-800-12 | 800.00V | 12.000A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P-1000-10 | 1000.0V | 10.000A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-8000P-1200-8 | 1200.0V | 8.0000A | 8000W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
| MPP-7500P-1500-5 | 1500.0V | 5.0000A | 7500W | RS485/RS232/Dry Node/Analog/USB/CAN/LAN |
Note: the above specifications are subject to update without notice
Product parameters
| Technical Data | 1KW/2KW/3KW | 6KW/8KW |
| AC: Input | ||
| – Voltage | 1ф220VAC±10% | 3ф380VAC±10% |
| – Frequency | 50-60Hz | |
| DC:Voltage | ||
| – Accuracy | <0.1% of rated value | |
| – Load regulation 0-100% | <0.05% of rated value | |
| – Line regulation ±10%△UAC | <0.05% of rated value | |
| – Regulation 10-100% load | <5ms | |
| – Slew rate 10-90% | <20ms-60s | |
| – Voltage compensation | <5% rated voltage | |
| – Ripple | <0.1% of rated value | |
| DC:Current | ||
| – Accuracy | <0.15% of rated value+20mA | |
| – Load regulation 1-100% | <0.1% of rated value | |
| – Line regulation ±10%△UAC | <0.05% of rated value | |
| DC:Power | ||
| – Accuracy | <0.3% of rated value | |
| Protection | Over Voltage Protection, Over Current Protection, Over
Power,Over temperature Protection and so on |
|
| Insulation | ||
| – AC input to enclosure | 1500VDC | |
| – AC input to DC output | 1500VDC | |
| – DC output to enclosure(PE) | Below 300V:500V(PE)
Below 1000V:1500V(PE) Below 2000V:2000V(PE)
|
|
| Other | ||
| – Digital interfaces | RS485/CAN (standard), RS232/USB/LAN (optional) | |
| – Analog interface (optional function) | 0-10V/4-20mA control power supply voltage/current output; 0-10V/4-20mA readback power supply voltage/current output;Dry contact start/stop | |
| – Cooling | Air cooling | |
| – Operation temperature | -5℃-45℃ | |
| – Storage temperature | -20℃-60℃ | |
| – Humidity | <80%,No condensation | |
| – Dimensions(W H D) | 325*88*450mm(1KW)
425*88*450mm(2KW&3KW) 425*132*551.5mm(6KW&8KW) |
|
| – Weight | 9KG(1KW)/14KG(2KW&3KW)/
25KG(6KW&8KW) |
|
Application Scenarios
- New Energy: EV battery testing, Li‑ion/fuel cell charge‑discharge aging, PV energy storage system testing.
- Aerospace: Avionics power testing, aerospace component aging validation, high‑precision voltage/current simulation.
- Semiconductor & Electronics: Power semiconductor (MOSFET/IGBT) testing, ATE integration, electronic equipment aging.
- Industrial Manufacturing: Industrial motor drive testing, precision plating/sputtering/surface treatment, long‑distance load power supply (remote compensation).
- Data Centers: Server power module testing, energy storage performance verification.
FAQ
Q1: Does the MPP‑P Series support parallel operation? Any limitations?
A1: Yes, it supports master‑slave parallel mode, but only for models ≤600V. Factory pairing is required, along with optional accessories (output cables, 120Ω CAN terminator, Ethernet cable). Parallel expands current/power with delay‑free CAN sync; series operation is not supported.
Q2: What are the accuracy and resolution? Is it suitable for high‑precision work?
A2: Industry‑leading specs: voltage accuracy <0.1%, current accuracy <0.15%, power accuracy <0.3%; resolution 1mV (voltage)/0.1mA (current). Remote compensation (5% max) eliminates cable drops, fully meeting precision plating, semiconductor testing, and surface treatment needs.
Q3: What communication interfaces are available? Does it support remote control?
A3: Standard RS485/CAN (CAN for parallel only); optional USB/LAN/dry contact/analog (0–10V/4–20mA control/readback). Local/remote mode switch enables remote setup, monitoring, and waveform debugging for ATE integration.
Q4: What are the benefits of constant‑power mode?
A4: Constant‑power auto‑ranging switches voltage/current limits automatically: high voltage at low current, high current at low voltage. One unit covers multiple combinations (e.g., 1000W: 60V30A, 100V15A), reducing equipment costs and improving utilization.
Q5: What protection features does it have? How reliable is it?
A5: OVP/OCP/OPP/UVP/undercurrent/short‑circuit protection cuts output on fault. Operating temp ‑5°C~45°C, storage ‑20°C~60°C, industrial‑grade design for stable long‑term operation in harsh environments.