MPS-3206 Series Adjustable DC Regulated Power Supply
•Parameters: 32V, 6A, 192W / 32V, 10A, 320W / 62V, 5A, 310W
•4-digit simultaneous display of voltage and current, accurate and easy to use
•Anti-misoperation design for voltage adjustment knob to prevent accidental rotation
•5 groups of storage for convenient quick recall
•Coarse and fine adjustment of voltage and current for quick setting, simple and easy to use
Product Brief
The MPS-3206 Series is a practical, high-efficiency adjustable DC regulated power supply covering three models: MPS-3206, MPS-3210, and MPS-6205. It supports output up to 62V/10A and 320W, features 4-digit LED display, 5-group parameter storage, adjustable OVP/OCP, anti-misoperation design, and coarse/fine dual adjustment. It delivers stable output, safe protection, and easy operation, ideal for R&D, aging test, electronic maintenance, and laboratory use.
Product Description
The MPS-3206 Series is a cost-effective, high-stability adjustable DC regulated power supply engineered for professional electronic testing and power supply scenarios. It includes three standard models: MPS-3206 (32V/6A/192W), MPS-3210 (32V/10A/320W), and MPS-6205 (62V/5A/310W), covering common low-voltage, medium-power testing requirements with strong compatibility.
This series adopts a 4-digit synchronous LED display for voltage and current, with high setting and readback accuracy (voltage ≤0.1%+1 digit, current ≤0.2%+3mA) and high resolution (10mV for voltage, 1mA for current) to support precise parameter control. To improve workflow efficiency, it is equipped with <strong>5 groups of parameter storage and recall</strong> (M1–M5), allowing users to save and call frequently used parameters with one key, greatly reducing repeated adjustment time in batch testing.
Safety is fully guaranteed by <strong>adjustable OVP/OCP protection</strong>. Over-voltage protection and over-current protection can be freely set within the rated range, automatically cutting off output to protect loads and equipment when abnormal conditions occur. The voltage adjustment knob uses an <em>anti-misoperation design</em> to avoid accidental changes during testing, ensuring stable and continuous output.
For flexible operation, the power supply supports coarse and fine adjustment dual mode for voltage and current: coarse adjustment for fast positioning and fine adjustment for precise calibration, matching the controllable output switch for safe and convenient start/stop control. In terms of reliability, it uses high-quality electronic components, stable cooling fan heat dissipation, and standard input compatibility with <strong>AC220V/110V±10%</strong>, adapting to global power grids. Compact size (115×96×261mm) and light weight (1.5kg) make it suitable for bench use in limited spaces.
| Model | MPS-3206 | MPS-3210 | MPS-6205 | |
| Rated input voltage | AC220V/110V±10% | |||
| Rated output voltage | 0 – 32V | 0 – 32V | 0 – 62V | |
| Rated output current | 0 – 6A | 0 – 10A | 0 – 5A | |
| Rated output power | 192W | 320W | 310W | |
| Load regulation | Voltage | <0.1%+5mV | <0.1%+10mV | <0.1%+5mV |
| Current | <0.2%+3mA | <0.2%+5mA | <0.2%+3mA | |
| Line regulation | Voltage | <0.01%+5mV | <0.01%+10mV | <0.01%+5mV |
| Current | <0.2%+3mA | <0.2%+5mA | <0.2%+3mA | |
| Setting accuracy | Voltage | ≤0.1%+1 digit | ≤0.1%+1 digit | ≤0.1%+2 digit |
| Current | ≤0.2%+3mA | ≤0.2%+5mA | ≤0.2%+3mA | |
| Setting resolution | Voltage | 10mV | 10mV | 10mV |
| Current | 1mA | 1mA | 1mA | |
| Readback accuracy | Voltage | ≤0.1%+1 digit | ≤0.1%+1 digit | ≤0.1%+2 digit |
| Current | ≤0.2%+3mA | ≤0.2%+5mA | ≤0.2%+3mA | |
| Readback resolution | Voltage | 10mV | 10mV | 10mV |
| Current | 1mA | 1mA | 1mA | |
| Ripple | Voltage | ≤10mVrms | ≤10mVrms | ≤10mVrms |
| Current | ≤5mArms | ≤5mArms | ≤5mArms | |
| OVP | 0 – 32V±0.2%FS | 0 – 32V±0.2%FS | 0 – 62V±0.2%FS | |
| Max. voltage | 32V±0.2% | 32V±0.2% | 62V±0.2% | |
| OCP | 0 – 6.1A±0.2%FS | 0 – 10A±0.2%FS | 0 – 5.1A±0.2%FS | |
| Max. current | 6.1A±0.2% | 10A±0.2% | 5.1A±0.2% | |
| Temperature Coefficient | Operation | 0 – 40℃≤80%RH | 0 – 40℃≤80%RH | 0 – 40℃≤80%RH |
| Temperature Coefficient | Storage | -15 – 70℃≤80%RH | -15 – 70℃≤80%RH | -15 – 70℃≤80%RH |
| Instrument size (WHD) | mm | 115*96*261 | ||
| Packing size (WHD) | mm | 167*153*317 | ||
| Net weight | kg | 1.5 | ||
| Gross weight | kg | 1.9 | ||
Application Scenarios
- R&D Prototype Verification: Provides stable adjustable power for electronic product development, circuit debugging, and performance validation.
- Product Aging Testing: Used for continuous power aging and reliability testing of small and medium-power electronic devices.
- Electronic Repair & Maintenance: Delivers accurate adjustable power for fault detection and repair of electronic equipment, home appliances, and circuit boards.
- Laboratory Research & Teaching: Suitable for school labs, training centers, and scientific research experiments requiring stable DC power.
- Production Line Quality Testing: Applied to functional testing and quality inspection on electronic production lines to ensure product consistency.
FAQ
Q1: What models are included in the MPS-3206 Series?
A1: The series includes three models: MPS-3206 (32V/6A/192W), MPS-3210 (32V/10A/320W), and MPS-6205 (62V/5A/310W).
Q2: What is the display specification of this power supply?
A2: It uses a 4-digit synchronous LED display for voltage and current. Voltage resolution is 10mV, current resolution is 1mA, with high accuracy and clear reading.
Q3: How to use the 5-group storage function?
A3: Set the required voltage and current parameters, long-press M1–M5 to save, and short-press the corresponding key to quickly recall, supporting one-key switching of common parameters.
Q4: Are OVP and OCP adjustable? How do they protect equipment?
A4: Yes, OVP and OCP can be adjusted freely within the rated range. When voltage or current exceeds the set threshold, the power supply automatically protects and cuts off output to prevent damage to the load and itself.
Q5: What is the anti-misoperation design?
A5: The voltage adjustment knob has an anti-misoperation structure to avoid accidental rotation during testing, keeping output parameters stable and improving test safety.
| Standard Accessories: | Power Cable*1PC, Test Lead*1PC, User Manual |
|---|