MTP-200 series two-way programmable DC power supply
•Output voltage: 0-30V/0-150V, etc.; Current: 0-6A/0-30A, etc.; Power: 600W-900W (2 channels for all)
•Two channels independently adjustable and isolated from each other
•List sequence output function
•Voltage compensation to eliminate line loss
•Standard RS232 interface, compatible with SCPI and Modbus protocols
•Suitable for ATE,system integration industry
Product Brief Introduction
| Model | MTP-201 | MTP-202 | MTP-203 | MTP-204 | MTP-205 | MTP-206 | MTP-207 | |
| Rated output voltage | 0~30V*2CH | 0~30V*2CH | 0~60V*2CH | 0~60V*2CH | 0~80V*2CH | 0~150V*2CH | 0~15V*2CH | |
| Rated output current | 0~20A*2CH | 0~30A*2CH | 0~10A*2CH | 0~15A*2CH | 0~11A*2CH | 0~6A*2CH | 0~60A*2CH | |
| Rated output power | 600W*2CH | 900W*2CH | 600W*2CH | 900W*2CH | 880W*2CH | 900W*2CH | 900W*2CH | |
| Ripple | 10mVrms | 10mVrms | 10mVrms | 10mVrms | 15mVrms | 15mVrms | 10mVrms | |
| Rated input voltage | AC 220V±10% | |||||||
| Voltage transformation method | Switching Mode Power Supply | |||||||
| Load regulation rate | Voltage | ≤0.1%+20mV | ≤0.1%+10mV | ≤0.1%+15mV | ≤0.1%+10mV | ≤0.1%+25mV | ||
| Current | ≤0.1%+5mA | ≤0.1%+5mA | ≤0.1%+5mA | ≤0.1%+5mA | ≤0.1%+8mA | |||
| Line regulation rate | Voltage | ≤0.1%+20mV | ≤0.1%+10mV | ≤0.1%+15mV | ≤0.1%+10mV | ≤0.1%+25mV | ||
| Current | ≤0.1%+5mA | ≤0.1%+5mA | ≤0.1%+5mA | ≤0.1%+5mA | ≤0.1%+8mA | |||
| Setting resolution | Voltage | 1mV | ||||||
| Current | 1mA | |||||||
| Settingaccuracy (25℃±5℃) | Voltage | ≤0.1%+10mV | ||||||
| Current | ≤0.3%+10mA | |||||||
| Read back resolution | Voltage | 1mV | ||||||
| Current | 1mA | |||||||
| Read back accuracy(25℃±5℃) | Voltage | ≤0.1%+10mV | ||||||
| Current | ≤0.3%+10mA | |||||||
| Temperature coefficient | Operating | 0 to 40℃≤85R.H. | ||||||
| Storage | -15 to 70℃≤85 R.H. | |||||||
| Machine size (W*H*D) | mm | 482*100*372 | ||||||
| Net weight | kg | 9.5 | ||||||
Product Description
The MTP-200 series adopts switching power conversion architecture and standard 19-inch 2U rack-mount cabinet with unified dimensions of 482×100×372mm and net weight of 9.5kg, compatible with industrial test racks and desktop bench placement. It supports universal AC 220V±10% single-phase input, stable operation under 0~40℃ and ≤85% non-condensing relative humidity, and storage temperature range of -15℃ to 70℃. Each unit has two completely separate output channels with full electrical isolation between them, enabling simultaneous power supply for two independent test objects without signal crosstalk interference.
In terms of output stability and measurement precision, all models share uniform 1mV voltage and 1mA current setting & readback resolution. Under standard 25℃±5℃ test environment, voltage setting accuracy ≤0.1%+10mV and current setting accuracy ≤0.3%+10mV. Load regulation and line regulation indicators differ by model based on voltage and current specifications; voltage ripple is controlled within 10~15mVrms to provide steady DC output for multi-channel component testing. The temperature coefficient is calibrated for long-term continuous operation without obvious parameter drift during aging cycles.
For front-panel interactive operation, dual parameter input methods are provided: direct digital entry via numeric keypad, and fine tuning through rotary adjustment knob. The instrument supports two core programmable test functions: editable List sequence output for unattended multi-condition cyclic testing, and storage & one-click recall of up to 9 groups of frequently used voltage/current parameter sets to boost repeated test efficiency. Dedicated SENSE remote compensation terminals are reserved on the rear panel to offset voltage drop on long output wires, ensuring precise voltage delivery at DUT terminals even with extended wiring distances.
Comprehensive safety protection system includes OVP overvoltage protection, OCP overcurrent protection and OTP overtemperature protection. The power supply automatically cuts off output once voltage, current or temperature exceeds preset safe thresholds to protect both the instrument and tested samples. An intelligent temperature-sensing fan dynamically adjusts rotation speed according to internal heat load, running silently under light load and accelerating heat dissipation under full 900W single-channel output to balance noise and cooling performance.
For automated test system integration, RS232 communication interface comes as standard hardware, fully supporting SCPI and Modbus remote control command sets for upper computer parameter configuration, real-time data reading and automatic test flow execution. USB, RS485 and LAN communication interfaces are optional factory pre-installed accessories and cannot be retrofitted by users after delivery. Standard delivery accessories include power cable, RS232 cable, two pairs of test leads, SENSE wire and complete user manual; official website provides downloadable product datasheet and programming documents for secondary development.
Application Scenarios
- Automated ATE Test System Integration: Match full-automatic mass production test benches to supply isolated dual-channel power for simultaneous testing of two groups of electronic components.
- Multi-Device Synchronous Laboratory Testing: Provide two independent power sources for comparative experiments of circuit boards, sensors and small power modules in R&D labs.
- Electronic Component Batch Aging Production: Utilize List sequence output and 9-group parameter storage to conduct parallel long-term aging screening of resistors, capacitors and power chips.
- New Energy Small Equipment Testing: Simulate dual independent power supply environments for lithium battery modules, vehicle small electronic control units and charging accessories.
- Industrial Multi-Channel Quality Inspection: Apply dual isolated channels for offline sampling performance verification of consumer electronics and communication hardware.
Product FAQ Dialogues
Q1 What is the core feature of the MTP-200 series compared with single-channel power supplies?
Q2 What programmable test functions does the MTP-200 integrate?
Q3 What is the function of the SENSE interface equipped on MTP-200?
Q4 What communication interfaces and control protocols does MTP-200 support?
Q5 What safety protection mechanisms are built inside the MTP-200 series?
| Standard Accessories: | Power Cable*1PC, RS-232, SENSE, Test Lead*2PC, User Manual |
|---|---|
| Optional Accessories (Manufacturer installed only): | LAN |